Data are reported on a number of controlled and uncontrolled sources from various metal decorating operations. Emission levels are related to process variables such as ink coverage, coater speed, sheet size, and applied coating film weight. Results are presented depicting variation of organic emission levels from a coating process line with elapsed process time. For controlled sources employing either catalytic or thermal incineration, conversion efficiencies are reported as a function of temperature. Operational curves are presented for each control system studied indicating the dependence of carbon dioxide, NOx, and organic output on incineration temperatures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.