Abstract
This paper proposes an adaptive neuro-fuzzy inference system (ANFIS) maximum power point tracking (MPPT) controller for grid-connected doubly fed induction generator (DFIG)-based wind energy conversion systems (WECS). It aims at extracting maximum power from the wind by tracking the maximum power peak regardless of wind speed. The proposed MPPT controller implements an ANFIS approach with a backpropagation algorithm. The rotor speed acts as an input to the controller and torque reference as the controller’s output, which further inputs the rotor side converter’s speed control loop to control the rotor’s actual speed by adjusting the duty ratio for the rotor side converter. The grid partition method generates input membership functions by uniformly partitioning the input variable ranges and creating a single-output Sugeno fuzzy system. The neural network trained the fuzzy input membership according to the inputs and alter the initial membership functions. The simulation results have been validated on a 2 MW wind turbine using the MATLAB/Simulink environment. The controller’s performance is tested under various wind speed circumstances and compared with the performance of a conventional proportional–integral MPPT controller. The simulation study shows that WECS can operate at its optimum power for the proposed controller’s wide range of input wind speed.
Highlights
Electricity is an undeniable source for the development of any nation
The effectiveness of the adaptive neuro-fuzzy inference system (ANFIS) maximum power point tracking (MPPT) controller for doubly fed induction generator (DFIG)-based wind energy conversion systems (WECS) under variable wind speed operation has been verified in MATLAB/Simulink environment
This paper proposed an ANFIS controller for maximum power extraction from the wind for grid-connected DFIG-based WECS
Summary
Electricity is an undeniable source for the development of any nation. Life cannot be imagined without electricity in any sector, whether residential, commercial, or industrial. According to the authors in [26,27], the operating point of the MPPT may be determined using the power-speed slope The disadvantage of this method is that it becomes unstable when the inertia of the turbine varies under a variable speed wind scenario [28]. While the TSR-based MPPT controller is easy to build and highly efficient, it has a high operating cost The drawback of this method is it needed optimal power coefficient and optimal tip-speed ratio [29].
Published Version (
Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have