Abstract
This work uses a continuous bubble-column scrubber for the absorption of CO2 with a 5M MEA solution under a constant pH environment to explore the effect of the pH of the solution and gas-flow rate (Qg) on the removal efficiency (E), absorption rate (RA), overall mass-transfer coefficient (KGa), liquid flow rate (QL), gas-liquid flow ratio (γ), and scrubbing factors (φ). From the outlet CO2 concentration with a two-film model, E, RA, KGa, QL, γ, and φ can be simultaneously determined at the steady state. Depending on the operating conditions, the results show that E (80-97%), RA(2.91x10-4-10.0x10-4mol/s-L), KGa (0.09-0.48 1/s), QL(8.74-230.8mL/min), γ (0.19-5.39), and φ (0.031-0.74 mol/mol-L) are found to be comparable with other solvents. In addition, RA, KGa, E, and QL have been used to correlate with pH and Qg, respectively, with the results further explained.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.