Abstract
Functioning of the giant axon of the isolated earthworm ventral nerve cord was examined during exposure to 6.45 GHz microwaves. We used continuous wave and pulsed irradiation, either synchronized with stimuli or asynchronous, lasting for 10–50 min at specific absorption rate from 30 to 230 W/kg. Action potential (AP) conduction velocity and the capability of nerve fiber to answer long-lasting high-frequency stimulation served as indices of microwave effect. Under some experimental conditions the nerve appeared to have extreme sensitivity to subtle temperature changes, induced by irradiation, but no non-thermal microwave effects were detected.