Abstract

Perioperative echocardiography is of paramount importance during cardiac surgery. Nonetheless, in the experimental large-animal setting, it might be challenging obtaining optimal imaging when using conventional imaging acquisition techniques, such as transthoracic and transesophageal screenings. Open-chest surgery allows epicardial echocardiographic assessment with direct contact between probe and heart, thus providing superior quality. Standard protocols regarding the use of epicardial ultrasound in swine for research purposes are lacking. Epicardial echocardiography was performed in 10 female German Landrace pigs undergoing cardiac surgery. A structured and comprehensive protocol for epicardial echocardiography was elaborated including apical, ventricular long and short axis, as well as epiaortic planes. All experiments were approved by the local board for animal welfare and conducted in accordance with the German animal protection law (TierSchG) and the ARRIVE guidelines. Systematic protocols using epicardial echocardiography may serve as an additional tool to assess cardiac dimensions and function in experimental scenarios with swine models.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.