Abstract

Energy conservation is an important issue in all sectoral activities, especially in processing industries such as natural gas refinery and liquefaction plant, petrochemical and cement mill in which energy isused in large amount. This paper presents a discussion on the experience in establishment and implementation the energy conservation program, including the reduction of greenhouse gas (GHG) emission achieved in the last four years in Arun LNG Plant, a commercial natural gas liquefaction plant in Aceh, Indonesia with a capacity of 2.2 million ton LNG per year. In addition, an analysis on the specific energy consumption and CO2 reduction is provided. The Energy Management Matrix was adopted in assessment of the energy management implementation in theArun LNG Plant. It was found that the efficiency of the plant tended to decrease from year to year, which was represented by the specificity of fuel consumption (accounted based on the LNG product). In 2010 the specific fuel consumption was 0.0088 mmscf per m3 LNG product; it was up to 0.0234 in 2013. Fortunately, it was observed that the specific CO2 reduction (calculated on the LNG product basis) increased during tlast four years; in 2010 and 2013 the specific CO2 reduction was 0.195 and 0.518 ton per 105 m3 LNG produced, respectively.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call