Abstract

The determination of molybdenum(VI) in aquatic media by polarography, voltammetry and adsorptive stripping voltammetry using the formation of a Mo-chlorate-mandalic acid complex at +100 mV (SCE) is described. The 3 sblank-detection limit is 0.1 nmol/l with differential pulse adsorptive stripping voltammetry (DPAdsSV, catalytic current). The calibration graphs are linear up to 200 nmol/l for the latter, 400 nmol/l for staircase voltammetry without accumulation time and 1 mg/l for staircase polarography. The accuracy of the DPAdsSV method was checked by analysis of a standard reference water material. The utility of differential pulse voltammetry was tested in different aquatic media, e.g., tap water, ground water, surface water.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.