Abstract
The determination of molybdenum(VI) in aquatic media by polarography, voltammetry and adsorptive stripping voltammetry using the formation of a Mo-chlorate-mandalic acid complex at +100 mV (SCE) is described. The 3 sblank-detection limit is 0.1 nmol/l with differential pulse adsorptive stripping voltammetry (DPAdsSV, catalytic current). The calibration graphs are linear up to 200 nmol/l for the latter, 400 nmol/l for staircase voltammetry without accumulation time and 1 mg/l for staircase polarography. The accuracy of the DPAdsSV method was checked by analysis of a standard reference water material. The utility of differential pulse voltammetry was tested in different aquatic media, e.g., tap water, ground water, surface water.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.