Abstract
In this paper, a comparative analysis of loss of coolant accident (LOCA) in hot leg and cold leg of primary circuit in a VVER 1200 nuclear power plant is investigated. The effect of break size on the severity of the accident is observed. The break size was varied in the range 200-11350 cm2. For all the accident scenarios, station blackout (SBO) condition is set up. Additionally, it is assumed that no ECCS (Emergency Core Cooling System) is available due to system malfunction. The whole scenario is simulated in PCTRAN (Personal Computer Transient Analyzer) software. Results reveal that with the increase in the size of the break area, the core uncovering time decreases sharply. However, for a break size of 2800 cm2 or smaller, the water level in the core doesn’t drop to zero, indicating that the core is partially uncovered throughout the accident scenario. In case of hot leg LOCA, the draining of the reactor vessel is observed to be more rapid compared to cold leg LOCA, while the core melting started earlier in case of cold leg.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.