Abstract

The lower voltage transfer ratio is one of the shortcomings of matrix converter. The upper limit of voltage transfer ratio under indirect space vector modulation is 0.866. In the course of experiments, it is found that the actual voltage transfer ratio is lower than the expected one. The main reason of this limit is deeply analyzed in the paper. In order to enhance the voltage transfer ratio, an adaptive modulation rate regulation method is proposed. The voltage transfer ratio can be enhanced by 9.75% using the proposed method. The disadvantages of the proposed method are also discussed. The applicable load types are given. Simulation and experimental results verify the theoretical analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.