Abstract

A new method to determine neutron sensitivity of uranium-type local power range monitors (LPRMs) has been developed. In this method, neutron sensitivity of LPRMs is obtained from alpha-ray current of 234U. The uncertainty of the calibration for neutron sensitivity using alpha-ray current was 2.1%, and the correlation coefficient of these neutron sensitivities was 0.868 (sample: 50 cases). Using this method, the neutron sensitivity can be obtained without irradiation tests of LPRMs in reactors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.