Abstract

Singular system analysis is a successful technique to separate oscillating components from a given signal. A methodology is proposed to apply this technique to the signals obtained from the LPRMs of a boiling water reactor core and extract the contributions of the in-phase oscillation and the out-of-phase oscillations from the LPRM readings during an unstable event. This methodology has been validated with synthetic signals and simulations of in-phase and out-of-phase oscillations of the Leibstadt reactor. Finally, one case of Ringhals I Stability Benchmark has been analysed.