Abstract

We propose a new permanent magnet system for Kibble balance experiments, which combines advantages of the magnet designs invented by the National Physical Laboratory (NPL) and by the Bureau International des Poids et Mesures (BIPM). The goal of the proposed magnet system is to minimize the coil-current effect and to optimize the shielding at the same time. In the proposed design, a permanent magnet system with two gaps, each housing a coil, is employed to minimize the coil current effect, by reducing the linear coil-current dependence reported for the single air gap design by at least one order of magnitude. Both air gaps of the magnet are completely surrounded by high-permeability material, and hence the coils are shielded from outside magnetic fields and no magnetic field leaks outside of the magnet system. An example of the new magnet system is given and the analysis shows that the magnetic field in the air gap can be optimized to meet the requirement to be used in Kibble balances.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call