A model explaining gate-charging damage in MOSFETs observed during inter-layer-dielectric (ILD)-related plasma processes is reported. It indicates that the charging damage associated with the ILD plasma process can be related to the effect of photoconduction and/or capacitive impedance coupling of plasma potential through the multiple ILD layers. The model leads to a conclusion that by placing a larger-area lower-layer metal (such as Metal-1) plate or polysilicon plate at the gate terminal of MOSFETs, this ILD process-related charging damage can be eliminated or significantly reduced due to a substantial reduction in the gate-to-substrate impedance of the transistors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.