Abstract

Under dynamic conditions, the signals of power system have time-varying magnitude and frequency, which might lead to considerable errors for synchrophasor measurement. The traditional discrete Fourier transform (DFT) based algorithms used in Phasor Measurement Unit (PMU) are hard to meet the requirements of measurement accuracy because of the existence of spectral leakage. A dynamic phasor measurement algorithm is proposed in this paper in which the input sampled data are considered as non-stationary signals with amplitude modulation-frequency modulation (AM-FM) form, and the measurement is achieved by AM-FM demodulation. An angle-shifted energy operator (ASEO) is used to extract the instantaneous amplitude and low pass differential filter is introduced for frequency estimation. Simulation results indicate that the proposed algorithm can effectively improve the phasor measurement accuracy and has very short response time for PMU under dynamic conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.