Abstract
The laser line scanners are coming to be frequently used in a field of dimensional inspection process. There are several phenomena that make the data acquisition more difficult. Particularly secondary reflection, direct reflection, scan overlapping, outlying points. The effect of these phenomena can be minimised by optimal setting of scanning parameters stated in this paper. The parameters were determined from an experimental measurements of 50 various parts. Additionally a thermal stability effect was measured at two types of Nikon scanners. The stabilisation time and the systematic error were determined for the scanner LC15Dx: 45 min, 20μm and 30 min and 37 μm for the LC60Dx scanner. It should help to prevent the systematic errors during the measurement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.