Abstract

AimEndoscopic Ultrasound (EUS) is one of the important diagnostic tests in patients with probable hepatobiliary or lung diseases. As it is an airborne procedure and due to the current COVID-19 pandemic, British Society of Gastroenterology and NICE guidelines have stated that patients who are undergoing EUS must be tested for COVID-19 within 3 days before the procedure. EUS must be considered deferring if the patient tests positive. The aim of this audit is to increase the proportion of patients being swabbed within 3 days/72 hours of the procedure to > 90% by the end of 2021.MethodA list of patients who underwent elective EUS in January (initial audit) and mid-May to mid-June (re-audit) were collected using Endosoft software. Afterwards, electronic patient record system was checked for the date of the COVID-19 swab and its results. This data was then recorded in a password-protected Excel spreadsheet and the proportion of the patients meeting the standard was calculated.ResultsThe results of the initial audit indicated that although 95.7% of swabs were done within 3 days of the procedure, only 40.9% were done within 72 hours. These results were discussed at a mortality and morbidity meeting, and recommendations were. Hence, in the re-audit, 98.4% of the swabs were done within 3 days of the procedure and the percentage of swabs being done within 72 hours increased to 95.2%.ConclusionsThe target of increasing the proportion of patients being swabbed within 3 days/72 hours of the EUS procedure to > 90% was met in mid-2021.