Abstract

We report on responses of hydrated and dehydrated cortical bone tissues to mechanical loading applied by a Vickers indenter. The Vickers indentations were imaged in two- and three-dimensions (2D and 3D) using confocal laser scanning microscopy (CLSM) to understand mechanical behavior of bone tissues. Serial optical sections of indentation patterns of dry and wet bones were collected using CLSM. The indention surface structures were mapped using topographical CLSM imaging. The observation of CLSM shows the fundamental indentation responses for both the hydrated and dehydrated bone tissues were plastic deformation. No visible fracture was observed in the Vickers indentation patterns in the wet bone tissue, while non-propagating lamellar microcracks occurred in the dry bone tissue. This indicates that drying resulted in increased brittleness of the bone tissue. The Vickers hardness values of dry bone tissue were significantly higher than those of wet bone tissue at any applied loads (analysis of variation, ANOVA, p < 0.05). The resolution limits of confocal microscopy were also discussed for bone tissue scanning.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.