Abstract

Object and purpose of research. This paper discusses neutral grounding switchboard of electric power system aboard Arktika icebreaker and estimates fault current for given neutral resistance. Materials and methods. The paper relies on the technical specifications of neutral grounding switchboard and follows common methods of electric engineering. Main results. Fault current estimates for neutral grounding switchboard of TPS-36-2M2 synchronous turbogenset. Design of the switchboard. Conclusion. Electric power system aboard Arktika icebreaker has neutral resistance rating of 600 Ohm, which corresponds to High-Resistance Grounding class. Neutral grounding switchboard discussed in this paper has been in operation since 2020.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.