Abstract
Natural convection heat transfer rates in a vertical pipe were measured for number from 2.1x to 1.2x. Using the analogy concept, heat transfer experiments were replaced by mass transfer experiments. A cupric acid - copper sulfate () electroplating system was adopted as the mass transfer system and the mass transfer rates were measured. Comparison of the results with the existing laminar and turbulent natural convection heat transfer correlations on a vertical plate showed very good agreements except for the high case, where the boundary layer inside the vertical pipe interferes. The agreements showed the usefulness of the analogy experiment method. Using 3 different anode size and 6 different geometrical configurations, the effects of the anode size and position were explored. As expected, the anode size and position do not affect the limiting currents for most cases. These results will be used as the experimental background for the positioning and sizing of the anodes for a more complex experiment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Transactions of the Korean Society of Mechanical Engineers B
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.