Abstract

Buildings and structures of complex architectural forms and large extent are subject to deformations under the influence of fluctuations in the temperature of the outside air, uneven sedimentation of the soil base, seismic phenomena and other causes. To prevent cracks in bearing and fencing structures, expansion joints are provided that cut the building into compartments. Proper design, construction and execution of expansion joints are of great importance in construction, as they provide the opportunity to provide long service life and fire resistance of the main load-bearing and enclosing structures of buildings, internal and external finishes. Normative requirements for the device and technical parameters of fire protection of expansion joints do not currently exist, and since the expansion joints are elements of load-bearing and enclosing structures, their fire resistance is determined in conjunction with the rest of the elements of fire protection barriers, use and application is regulated by the norms of Russian federal legislation. To increase the overall fire resistance of the construction, special fire barriers are used, which are installed inside the expansion joints. The article gives an overview of the fire barriers of expansion joints of both foreign and domestic producers. It is shown that for the protection of expansion joints in a fire, fire barriers are used, specially designed for use in expansion joints, which are guaranteed to work with compression, stretching and shear. It has been established that the production of innovative fire-retardant materials is one of the main tasks of fire safety, this is also the way of the consistent transformation of the idea into a product that passes through the stages of research, design development, production and realization in civil and industrial buildings. It is necessary to choose a comprehensive solution that ensures the maximum satisfaction of the requirements when performing fire protection work to protect the expansion joint when exposed to a fire. The authors declare that the structures (products) intended for fire protection of the expansion joint should provide a stable own mechanical tensile strength of at least 40 %; at least 50 % compression; for a shift of not less than 20 %, the retention of elastic properties at the manufacturer’s declared maximum tensile-compressive stress per product of not less than 100 cycles. After the test, the structures (articles) should not have mechanical damages and deformation of the filler, as well as the manufacturer’s declared fire resistance tested with at least 20 % expansion from the design width of the expansion joint. The listed parameters are recommended to be presented in the technical documentation of the manufacturer of the construction (product) of fireproof filling for the expansion joint. All designs (products), whose parameters do not meet the requirements indicated above, should be attributed to the products to protect the other types of joints. When using other fillers for the fire barrier, it is recommended that the above requirements be met using material that provides deformation characteristics, both in the compression of the joint and during its stretching, and in the shear, during the entire period of the intended use. Particular attention should be paid to the technology of interfacing the structures (products) of fire barriers when they are installed in expansion joints along the entire length, which is guaranteed to prevent the appearance of technological gaps and voids. Proceeding from the experience of operating such sealing products, it is extremely important that the design of the fire-resistant seal allows during operation to observe the possible formation of gaps between the protected surface of the structure and the deformation body of the billet.

Highlights

  • Buildings and structures of complex architectural forms and large extent are subject to deformations under the influence of fluctuations in the temperature of the outside air, uneven sedimentation of the soil base, seismic phenomena and other causes

  • To prevent cracks in bearing and fencing structures, expansion joints are provided that cut the building into compartments

  • Construction and execution of expansion joints are of great importance in construction, as they provide the opportunity to provide long service life and fire resistance of the main load-bearing and enclosing structures of buildings, internal and external finishes

Read more

Summary

ÎÃÍÅÇÀÙÈÒÀ ÄÅÔÎÐÌÀÖÈÎÍÍÛÕ È ËÈÍÅÉÍÛÕ ØÂÎÂ ÇÄÀÍÈÉ È ÑÎÎÐÓÆÅÍÈÉ

Äàí îáçîð îãíåñòîéêèõ çàäåëîê äåôîðìàöèîííûõ øâîâ êàê çàðóáåæíûõ, òàê è îòå÷åñòâåííûõ ïðîèçâîäèòåëåé. Ê äåôîðìàöèîííûì øâàì ïðåäúÿâëÿþòñÿ îïðåäåëåííûå òðåáîâàíèÿ ïî îãíåñòîéêîñòè, òàê æå êàê è ê ïåðåêðûòèÿì, ñòåíàì è ïåðåãîðîäêàì, êîòîðûå îïðåäåëÿþòñÿ ñîãëàñíî íîðìàòèâíîé äîêóìåíòàöèè ïî ïîæàðíîé áåçîïàñíîñòè ñòðîèòåëüíîé êîíñòðóêöèè â öåëîì. Äëÿ óâåëè÷åíèÿ îãíåñòîéêîñòè êîíñòðóêöèè ïðèìåíÿþò ðàçëè÷íûå âèäû îãíåñòîéêîé çàäåëêè, êîòîðóþ óñòàíàâëèâàþò âíóòðè äåôîðìàöèîííûõ øâîâ  íàñòîÿùåå âðåìÿ èñïûòàíèÿ íà îãíåñòîéêîñòü ïðîâîäÿòñÿ äëÿ îãíåñòîéêîé çàäåëêè äåôîðìàöèîííîãî êîíñòðóêòèâíîãî øâà, ñîñòîÿùåé èç òåðìîðàñøèðÿþùåãîñÿ ãåðìåòèêà è âíóòðåííåãî çàïîëíåíèÿ øâà ìèíåðàëüíîé âàòîé; ïðåäåëû îãíåñòîéêîñòè, êàê ïðàâèëî, ìîãóò ñîñòàâëÿòü EI 90 ïðè ïëîòíîñòè ìèíåðàëüíîé âàòû äî 110 êã/ì3 è ÅI 180 ïðè ïëîòíîñòè íå ìåíåå 110 êã/ì3 Öåëü íàñòîÿùåãî èññëåäîâàíèÿ çàêëþ÷àåòñÿ â ðàññìîòðåíèè òèïîâ äåôîðìàöèîííûõ øâîâ è â èçó÷åíèè ïðèìåíåíèÿ îãíåñòîéêîé çàäåëêè — ìàòåðèàëîâ (èçäåëèé), êîòîðûå óñòàíàâëèâàþòñÿ â ãîðèçîíòàëüíûå è âåðòèêàëüíûå äåôîðìàöèîííûå øâû ìîíîëèòíûõ è ñáîðíûõ æåëåçîáåòîííûõ êîíñòðóêöèé çäàíèé è ñîîðóæåíèé ðàçëè÷íîãî íàçíà÷åíèÿ è îáåñïå÷èâàþò íåðàñïðîñòðàíåíèå è ëîêàëèçàöèþ ïîæàðà â òå÷åíèå òðåáóåìîãî ïåðèîäà âðåìåíè

Íåîáõîäèìîñòü èñïîëüçîâàíèÿ îãíåçàùèòû äåôîðìàöèîííûõ øâîâ
Ïàðàìåòð Parameter
Findings
ÑÏÈÑÎÊ ËÈÒÅÐÀÒÓÐÛ
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call