Abstract

This paper presents a new hybrid dc circuit breaker producing no conducting power loss under normal operating conditions and having the capability to interrupt a large amount of short-circuiting current within several milliseconds. It consists of two reactors for current limiting and current control, two mechanical contactors, and a multilevel converter based on the cascade connection of multiple full-bridge dc/dc converter cells. It is characterized by achieving current commutation from the main mechanical contactor to the multilevel converter with fast current control. This results in eliminating auxiliary power semiconductor switches that produce a non-negligible conducting power loss under normal operating conditions. This paper discusses both principles of operation and control method of the new hybrid dc circuit breaker. Experimental verification is performed by a downscaled system rated at 300V and 150A, along with verification by computer simulation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.