Abstract
To calibrate the detection efficiency of a plastic scintillator that detects prompt gamma quanta from the 19F(p,αγ)16O resonant reaction of radiative proton capture and is used to control the dynamics of the arrival of protons with an energy of about 340 keV accelerated by a magnetically isolated pulsed ion diode, a change the polarity of the diode electrodes to the reverse was used, at which electron bunches were accelerated in the geometry of the Luce diode, forming virtual cathodes. The virtual cathodes in the Luce diode collectively accelerated protons to an energy of about 500 keV, the value of which was determined from the drift velocity of these virtual cathodes, while the number of such protons was determined from the activity of the 13N radionuclide induced by the 457 keV resonance of the 12C(p,γ)13N reaction.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.