Abstract

Fault current heating of the current limiting modules made of 2G HTS tapes and stabilized with stainless steel was studied. It is demonstrated that the speed of current limiting element heating hardly depends on the degree of the stainless steel stabilization. The ways to improve the heat transfer with the help of the increase of the elements’ surface area were demonstrated with the use of a mathematical model taking into account parameters of heat transfer to liquid nitrogen.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.