ObjectiveThis study compared the quantity of extruded debris after instrumentation with TRUShape 3D Conforming files, TruNatomy files, and the WaveOne Gold reciprocating system.Materials and methodsFifty-one mesiobuccal canals with severe curvatures (25–40°) were assigned to three equal groups according to the rotary system used for preparation, either TRUShape, TruNatomy, or WaveOne Gold files. The extruded debris was collected in pre-weighed glass vials. The data were statistically analyzed using a one-way ANOVA test and Tukey’s post hoc test.ResultsThe least extruded debris was obtained with the WaveOne Gold instruments compared to the TRUShape and TruNatomy files (p < 0.001).ConclusionsDebris extrusion occurs independently of the motion or design of the instrument. The WaveOne Gold system outperformed TRUShape and TruNatomy files in this study.