ObjectivesThe primary purposes of this study were to measure axial rotation during supine cervical spinal manipulative therapy (cSMT) and to record recipients’ and doctors’ perceptions of rotational magnitudes. MethodsExperienced doctors of chiropractic (DCs) provided supine cSMT and acted as recipients of cSMT. Participants who received SMT wore inertial measurement units attached to the forehead and sternum for motion capture. Afterward, recipients and DCs completed questionnaires asking about their perceptions of motion. Data were analyzed for magnitudes of axial rotation at peak thrust and correlations with patient and doctor perceptions. Secondary analyses included angular velocity, angular acceleration, and other kinematic variables. ResultsWe recorded 23 SMT events with 14 DCs. Rotation at thrust peaks averaged 32.4° (17.4°). Doctors’ and recipients’ perceptions of rotation were higher than measured values 45% and 50% of the time, respectively. Maximum angular velocity and acceleration averaged 221.9°/s (124.9) and 4786.5°/s2 (2456.6), respectively. We found no correlation between perceptions and velocity or acceleration; doctors’ perceptions had an inverse correlation with measurements. ConclusionOn average, we found rotation during supine cSMT to be 32°. Both DCs and SMT recipients overestimated rotation compared with actual measurements. These factors should be considered in discussions of rotation and SMT.
Read full abstract