BackgroundThere might be a beneficial effect of transient ulnar artery compression in prevention of radial artery occlusion (RAO) after trans-radial catheterization. ObjectiveThe objective of this study was to assess, by Duplex ultrasound, the efficacy of simultaneous ulnar and radial artery compression (SURC), in prevention of RAO, compared to conventional and patent hemostasis techniques. Patients and methodsFour hundred and fifty consecutive patients undergoing elective trans-radial catheterization were enrolled. Patients were randomized in 1:1:1 fashion into 3 groups; conventional hemostasis (Group A, n = 150 patients), patent hemostasis (Group B, n = 150 patients), and SURC technique (Group C, n = 150 patients). RAO was assessed by duplex ultrasound at 1-h post TR band removal (primary endpoint), and at 1-month. ResultsThe primary endpoint, RAO 1-h post TR-band removal, was significantly lower among patients of group C as compared to those of group A and B (1.3%, 6.7%, and 7.3%, respectively –p = 0.03). This was still consistent at 1-month (0.7%, 8%, and 6%, respectively –p = 0.03). Multiple regression analyses revealed that lower radial artery diameter (RAD) after flow-mediated dilatation (FMD) independently predicted RAO at 1-h, while RAD at 1-h post-TR band removal was the only independent predictor of RAO at 1-month. Receiver operator characteristic (ROC) analysis showed that RAD at 1-h post-TR band removal at cut-off ≤1.75 mm could predict RAO at 1-month with high accuracy (AUC = 0.9, CI = 0.8–1.0, p < 0.001–86% sensitivity, and 95% specificity). ConclusionA technique of SURC is associated with less incidence of early and late RAO compared to conventional hemostasis techniques.