This paper presents an empirical table-based nonlinear HEMT model fully extracted from time-domain large-signal measurements. A simple and direct extraction procedure, based on a vector nonlinear network analyzer measurement system with load-pull facilities, demonstrates by experimental results on microwave transistors how a very reduced number of measurements is enough to obtain the current and charge generators to fill a lookup model. Table-based model extraction, implementation, and validation are described in this paper.