An experimental study to develop beam stops for the next generation of neutral beam injectors was started, using an ion source developed for the JT-60 neutral beam injector. A swirl tube is one of the most promising candidates for a beam stop element which can handle steady-state and high-heat flux beams. In the present experiments, a modified swirl tube, namely an externally-finned swirl tube, was tested together with a simple smooth tube, an externally finned tube, and an internally finned tube. The major dimensions of the tubes are 10 mm in outer-diameter, 1.5 mm in wall thickness, 15 mm in external fin width, and 700 mm in length. The burnout heat flux (CHF) normal to the externally finned swirl tube was 4.1 ± 0.1 kW/cm 2 , where the Gaussian e-folding half-width of the beam intensity distribution was about 90 mm, the flow rate of the cooling water was 30 l/min, inlet and outlet gauge pressures were about 1 MPa and 0.2 MPa, respectively, and the temperature of the inlet water was kept to 20 °C during a pulse. A burnout heat flux ratio, which is defined by the ratio of the CHF value of the externally-finned swirl tube to that of the externally-finned tube, turned out to be about 1.5. Burnout heat fluxes of the tubes with a swirl tape or internal fins increase linearly with an increase of the flow rate. It was found that the tube with external fins has effects that not only reduce the thermal stress but also improve the characteristics of boiling heat transfer.