Tinnitus is a multifactorial phenomenon with quality-of-life detriments for those affected by it. We aim to establish a relationship between subjective tinnitus severity with objective audiometric data in the extended high frequency (EHF) from 9 to 16 khz and with distortion product otoacoustic emissions (DPOAE). We hypothesize that severe subjective tinnitus as measured by the Tinnitus Handicap Inventory (THI) does not correlate with increased hearing thresholds in the EHF range. Prospective. Single Tertiary Care Center. Patients identified with tinnitus and normal hearing thresholds within standard frequency range (250-8000 Hz) were consented for participation. Those with underlying otologic disease, trauma, radiotherapy, or ototoxic drug use were excluded. The THI questionnaire was given to eligible patients and audiometric test results were collected. THI scores were categorized by severity groups. An n = 20 to 30 was determined to have an effect size of 0.7 with a significance level of P = .05. THI and audiometric data were collected for 38 patients and categorized into mild (n = 18, 47.4%), moderate (n = 8, 21.1%), slight (n = 7, 18.4%), and severe (n = 5, 13.2%) tinnitus severity groups. Mean THI score was 32.3 ± 19.6 with a statistically significant difference in scores by assigned THI severity group (P < .01). There were no significant differences or linear relationship among hearing thresholds in EHF range or DPOAE stratified by subjective tinnitus group (P = .49, r2 = 0.10) CONCLUSION: Subjective tinnitus severity is not predictive of audiometric outcomes. This finding can be used as a counseling tool to help tinnitus patients manage symptoms, expectations, and overall treatment outcomes.
Read full abstract