AbstractThe U.S. National Lightning Detection Network (NLDN) detection efficiency (DE) and classification accuracy (CA) for cloud discharge (IC) activity (identified here by a sequence of non‐return‐stroke‐type electric field pulses not accompanied by channels to ground) were evaluated using optical and electric field data acquired at the LOG (Lightning Observatory in Gainesville), Florida. Our ground truth “IC events” include 26 “isolated IC events” (complete IC flashes), 58 “IC events before first return stroke,” and 69 “IC events after first return stroke.” For the total of 153 IC events, 33% were detected by the NLDN, and the classification accuracy was 86%. For complete IC flashes, the detection efficiency and classification accuracy were 73% and 95%, respectively, and the average number of NLDN‐reported cloud pulses was 2.9 per detected event. For 24 preliminary breakdown pulse trains in CG flashes, the detection efficiency and classification accuracy were 46% and 82%, respectively. We have additionally estimated the DE and CA for return strokes in CG flashes. Irrespective of stroke order and polarity, the DE was 92% (339/367), and the CA was also 92% (312/339). The DEs for negative first and subsequent strokes were 98% and 90%, respectively.