BackgroundThe surgical treatment for mandibular repositioning using a bilateral sagittal split osteotomy (BSSO) favours the development of techniques that result in adequate repair and stability. In Puricelli’s mandibular sagittal split osteotomy (PMSSO) proposal, the vertical lateral cut osteotomy is located in the interradicular space between the lower first molar and second premolar.ObjectivesThis in silico study aimed to investigate the mechanical stability of PMSSO and compare it with the classical Obwegeser–Dal Pont technique for mandibular advancement.Materials and methodsA computational geometric model of the mandible was created in a virtual environment using computer-aided design (CAD) software. After reproducing the advancements, two test groups were developed: GTOD10, Obwegeser–Dal Pont osteotomy, and GTP10, Puricelli osteotomy, both simulating a 10-mm mandibular advancement, allowing for measuring the area of overlap between bone segments. With the geometric changes promoted by the osteotomy, boundary conditions of displacement and force were applied to a CAD software based on finite element analysis (FEA), allowing for quantitative and comparative analysis of the stress and vertical displacement of the mandible, mechanical measurements that may be associated with strength and stiffness.ResultsA 17.48% higher stress was observed in the GTP10 group than in GTOD10. However, the region of highest stress in GTP10 was found in a part of the bone that was still intact and far from the area of fragility caused by lateral vertical osteotomy. In contrast, in GTOD10, the region with high stress was in a less resistant bone region. The GTP10 group showed a 28.73% lower displacement than GTOD10. The area of overlap between the proximal and distal segments of the mandible was 33.13% larger in the GTP10 than in the GTOD10 group.ConclusionThe PMSSO method, performed in large mandibular advancements, keeps the point of highest stress away from the mandibular fragility zone. Considering the same amount of advancement, it also promotes less displacement and larger areas of bone overlap.Clinical relevanceThe results suggest that PMSSO, applied in large mandibular advancement, presents greater postoperative stability.