BackgroundSurgical site infection (SSI) is a major problem following total hip arthroplasty (THA). This study investigated the impact of a standard intraoperative routine where the surgical team wears full-body exhaust suits (space suits) within a laminar airflow (LAF)-ventilated operating room (OR) on environmental contamination. Our primary objective was to identify potential modifiable intraoperative factors that could be better controlled to minimize SSI risk.MethodsWe implemented an approach involving simultaneous and continuous air sampling throughout actual primary cementless THA procedures. This method concurrently monitored both airborne particle and microbial contamination levels from the time the patient entered the OR for surgery until extubation.ResultsAirborne particulate and microbial contamination significantly increased during the first and second patient repositionings (postural changes) when the surgical team was not wearing space suits. However, their concentration exhibited inconsistent changes during the core surgical procedures, between incision and suturing, when the surgeons wore space suits. The microbial biosensor detected zero median microbes from draping to suturing. In contrast, the particle counter indicated a significant level of airborne particles during head resection and cup press-fitting, suggesting these procedures might generate more non-viable particles.ConclusionsThis study identified a significant portion of airborne particles during the core surgical procedures as non-viable, suggesting that monitoring solely for particle counts might not suffice to estimate SSI risk. Our findings strongly support the use of space suits for surgeons to minimize intraoperative microbial contamination within LAF-ventilated ORs. Therefore, minimizing unnecessary traffic and movement of unsterile personnel is crucial. Additionally, since our data suggest increased contamination during patient repositioning, effectively controlling contamination during the first postural change plays a key role in maintaining low microbial contamination levels throughout the surgery. The use of sterile gowns during this initial maneuver might further reduce SSIs. Further research is warranted to investigate the impact of sterile attire on SSIs.