To provide reference for the design of the air-suction tea sorting device, the coupled numerical simulation model was established by the coupling method of computational fluid dynamics (CFD) and discrete element method (DEM) with tea of different quality as test objects, and the model was verified experimentally. Regarding tea particles of different quality, when the test tea particle mass was 0.215, the test value was located in the simulation value with a minimum error of 9 mm, which an error rate of 3.33%, and maximum error of 19 mm, with an error rate of 7.03%. When the test tea particle mass was 0.145, the minimum error of the test value was 5 mm and the error rate was 1.54%, and the maximum error was 9 mm and the error rate was 3.33%. The verification results established the accuracy of the model. During the suspension test and simulation, tea particles were affected by the air flow field of the observation tube, and tea particles fluctuated. During suspension, tea particles were attached to the inner wall of the observation tube under the action of the air flow field. An in-depth study showed that the relationship between the different distances from the initial position of the particles during suspension and the simulation time was a peak function. The extreme function is used to fit the actual trajectory, and the fitting degree is good. The fitting degree of the particle closest to the initial position was 0.9455, and the fitting degree of the particle farthest from the initial position was 0.9981.