Extremely early diagnosis of human immunodeficiency virus (HIV) infection has been considered highly important for its treatment. We conducted a performance assessment of a newly developed rapid diagnostic reagent for HIV by using a fourth-generation immunochromatographic assay (Alere HIV Combo). We used whole-blood, plasma, and serum samples obtained from 250 Japanese adults who visited the Kawasaki Medical School Hospital and underwent HIV screening tests. We also used 12 types of commercial HIV-1 sero- conversion panels and World Health Organization standard antigens. This method, which has a detection sensitivity of 100% and a specificity of 99.3%, was as accurate as the chemiluminescent immunoassay (CLIA) method. In a sensitivity test using seroconversion panels in the early phase of infection, the mean duration until positive conversion was 19.3 days. With this method having a high detection sensitivity for HIV-1p24 antigen, the results from whole-blood samples were the same as those from plasma and serum samples. Therefore, it can be considered as a useful rapid measurement method for general practice.