Background: Continuous glucose monitoring (CGM) improves neonatal outcomes in type 1 diabetes pregnancies; however, its effectiveness has not been assessed in a real-world setting in the United States. Objective: The Triple C Study aimed to examine the clinical effectiveness, assessed through maternal glucose control and gestational health outcomes, of CGM use compared with self-monitoring of blood glucose (SMBG) in pregnancies associated with type 1 diabetes in a real-world setting. Research Design and Methods: We retrospectively identified 160 type 1 diabetes pregnancies at the Barbara Davis Center for Diabetes managed with CGM therapy (n = 109) or SMBG (n = 51) over a 6.5-year period (2014-2020). Obstetric care was provided at multiple practices. CGM use was defined as ≥60% wear in the second and third trimesters of pregnancy. Data were obtained from the electronic medical record system, hospital records, and vital statistics departments (Colorado and Wyoming). We used Student's t-test for continuous variables and chi-square test for categorical variables to compare outcomes between groups. Results: The CGM group had more participants meeting trimester-specific hemoglobin A1C (HbA1c) goals throughout pregnancy and postpartum (P < 0.01 in each time period). The CGM group had fewer participants never meeting HbA1c goals in any trimester than the SMBG group (P < 0.001). There were no significant differences in neonatal outcomes between groups, other than for macrosomia (12.8% CGM vs. 29.4% SMBG, P = 0.01). Infants of CGM users required a neonatal intensive care unit admission less often (52.9% CGM vs. 68.3% SMBG, P = 0.0989). Conclusions: CGM use was associated with improved maternal glucose levels in a diverse real-world cohort.