Recently, the author has shown elsewhere a simplified model that allows quick evaluations of the annual overall energy collected by a surrounding heliostat field. This model is the combination of an analytical flux density function produced by a heliostat, developed by the own author, and an optimized mirror density distribution developed by University of Houston for the Solar One Project. As main conclusion of this previous work, it was recognized that such pseudo-continuous simplified model should not substitute much more accurate discrete evaluations, which manage thousands of individual heliostat coordinates. Here in this work, the difficulty of generating a preliminary discrete layout of a large number of heliostats is addressed. The main novelty is the direct definition of thousands of heliostat coordinates through basically two parameters i.e. a simplified blocking factor and an additional security distance. Such procedure, which was formerly theoretically suggested by the author, is put into practice here, showing examples and commenting their problems and advantages. Getting a previous set of thousands of heliostat coordinates would be a major first step in the complex process of designing solar power tower (SPT).