Combustible biomass dusts are formed at various handling stages, and accumulations of these dusts can occur on hot surfaces of electrical and mechanical devices and can pose fire risks. This study evaluates the ignition characteristics of dust from two types of biomass commonly used in the U.K. power stations: herbaceous miscanthus and woody pine. The ignition risks of the individual biomass and their blends in two different weight ratios, 90 wt % pine to 10 wt % miscanthus and 50 wt % pine to 50 wt % miscanthus, were investigated. Biomass–biomass blends represent the power plant scenario where a number of biomass are fired under daily operation, and thus, dust sedimentation could consist of material blends. The influence of washing pretreatment (particularly to remove catalytic potassium) on the ignition behavior of these dusts was investigated. Fuel characterization via proximate and ultimate analyses was performed on all fuels and combustion characteristics via thermogravimetric analysis (TGA). The ris...