Purpose Intravenous sedation has been well accepted to allow dental restoration in uncooperative children while avoiding aspiration and laryngospasm; however, intravenous anesthetics such as propofol may lead to undesired effects such as respiratory depression and delayed recovery. The use of the bispectral index system (BIS), a monitoring system reflective of the hypnotic state, is con-troversial in the reduction in the risk of respiratory adverse events (RAEs), recovery time, the in-travenous drug dosage, and post-procedural events. The aim of the study is to evaluate whether BIS is advantageous in pediatric dental procedures. Methods A total of 206 cases, aged 2-8 years, receiving dental procedures under deep sedation with propofol using target-controlled infusion (TCI) technique were enrolled in the study. BIS level was not monitored in 93 children whereas it was for 113 children, among which BIS values were maintained between 50-65. Physiological variables and adverse events were recorded. Statistical analysis was conducted using Chi-square, Mann Whitney U, Independent Samples t and Wilcoxon signed tests, with a p value of <0.05 considered to be statistically significant. Results Although no statistical significance in the post-discharge events and total amount of propofol used was observed, a clear significance was identified in periprocedural adverse events (hypoxia, apnea, and recurrent cough, all p value < 0.05) and discharge time (63.4 ± 23.2 vs. 74.5 ± 24.0 min, p value < 0.001) between these two groups. Conclusions The application of BIS in combination with TCI may be beneficial for young children undergoing deep sedation for dental procedures.