Supraglottic masses can be an anaesthesiologist's nightmare due to the difficult airway scenario and bleeding risk during airway manipulation. Awake fibreoptic intubation is the primary method to secure the airway in such cases. However, most practising anaesthesiologists are not experts at handling the fibreoptic scope, especially in cases with a floppy supraglottic mass where it becomes difficult to displace the mask with the thin flexible bronchoscope. A hybrid technique of intubation in supraglottic masses using Bonfils rigid scope and C-MAC is often described but frequently not available. Here we describe a case of an elderly patient in their 80s presenting with a floppy supraglottic mass where an awake fibreoptic bronchoscope failed to secure the airway. Without access to a rigid Bonfils scope, we intuitively used a C-MAC to visualize the larynx and a yankauer suction catheter to displace the mass and perform a bougie-guided endotracheal intubation.
Read full abstract