Abstract

Supraglottic masses can be an anaesthesiologist's nightmare due to the difficult airway scenario and bleeding risk during airway manipulation. Awake fibreoptic intubation is the primary method to secure the airway in such cases. However, most practising anaesthesiologists are not experts at handling the fibreoptic scope, especially in cases with a floppy supraglottic mass where it becomes difficult to displace the mask with the thin flexible bronchoscope. A hybrid technique of intubation in supraglottic masses using Bonfils rigid scope and C-MAC is often described but frequently not available. Here we describe a case of an elderly patient in their 80s presenting with a floppy supraglottic mass where an awake fibreoptic bronchoscope failed to secure the airway. Without access to a rigid Bonfils scope, we intuitively used a C-MAC to visualize the larynx and a yankauer suction catheter to displace the mass and perform a bougie-guided endotracheal intubation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.