Ultrasonic techniques have been applied to assess crucial physical parameters in various types of fuels including the speed of sound (SoS), the bulk modulus and the acoustic attenuation coefficient. Such investigations may have important practical significance as the knowledge of fuel properties is directly related to the analysis of combustion characteristics, engine’s overall performance and exhaust emission in the environment. Nevertheless, typical pulse-echo acoustic methods, require the exact determination of both acoustic source – reflector distance and the time of flight of a finite temporal width ultrasonic pulse, setting thus an upper limit as regards the accuracy of the measurements. To encounter these challenges, we present a novel technology implemented through a low-cost and potentially portable optoacoustic interferometric characterization system (OPTICS) for the investigation of SoS variations in common fuels including automotive diesel, hydrous ethanol and gasoline. At 25 °C, diesel/kerosene blends demonstrated a SoS variation ranging from 1322.91 m/s (0.6 diesel volume fraction) to 1349.79 m/s (diesel fuel only), whereas hydrous ethanol samples varied between 1199.92 m/s (0.95 ethanol volume fraction) to 1149.39 m/s (pure ethanol only). Finally, assessments for 95 and 100 research octane number (RON) gasoline blends showed a SoS range from 1134.42 m/s (RON 95) to 1159.86 m/s (RON 100). The high precision and repeatability (relative uncertainty: ∼10-4) of the performed SoS measurements in controlled samples, has demonstrated the promising potential of OPTICS for the evaluation of fuel physical properties as well as the potential detection of contamination with adulterants.
Read full abstract