In the frame of heavy liquid metal (HLM) technology development, CIRCE pool facility at ENEA/Brasimone Research Center was updated by installing ICE (Integral Circulation Experiments) test section which simulates the thermal behavior of a primary system in a HLM cooled pool reactor. The experimental campaign led to the characterization of mixed convection and thermal stratification in a HLM pool in safety relevant conditions and to the distribution of experimental data for the validation of CFD and system codes. For this purpose, several thermocouples were installed into the pool using 4 vertical supports in different circumferential position for a total of 119 thermocouples [1][2].The aim of this work is to investigate the capability of the system code RELAP5-3D© to simulate mixed convection and thermal stratification phenomena in a HLM pool in steady state conditions by comparing code results with experimental data. The pool has been simulated by a 3D component divided into 1728 volumes, 119 of which are centered in the exact position of the thermocouples. Three dimensional model of the pool is completed with a mono-dimensional nodalization of the primary main flow path. The results obtained by code simulations are compared with a steady state condition carried out in the experimental campaign. Results of axial, radial and azimuthal temperature profile into the pool are in agreement with the available experimental data Furthermore the code is able to well simulate operating conditions into the main flow path of the test section.