Two series of post-tensioned concrete masonry walls subjected to uniform lateral loading were tested to investigate their flexural strength behaviour. Each series of walls consisted of four full-scale prestressed specimens, with varying levels of prestressing force, and one reinforced specimen. Of particular interest were the load–deflection curves, initial cracking loads, wall stiffness, crack patterns, and ultimate failure loads. An air bag test apparatus was used for applying lateral uniform pressures to the specimens. Results of this experimental investigation showed that, for a given wall thickness, increased prestressing force increases the cracking load, initial wall stiffness, and ultimate failure load. The results have established a linear relationship between increased prestressing force and initial cracking load, initial wall stiffness, and ultimate failure load. The proposed model, which takes into account changes in wall stiffness after initial cracking of the wall, accurately predicts wall behaviour. Key words: masonry, prestressed, walls, strength, behaviour, uniform, pressure, experimental, analytical.