Abstract

In this chapter, the behavior of PT-MWs is investigated using a database of tested walls. The accuracy of ignoring elongation of PT bars which is considered in the current masonry standard joint committee (MSJC in Building code requirements for masonry structures, ACI 530/ASCE 5, TMS 402, American Concrete Institute, Detroit, 2013) code in evaluating the strength of PT-MWs is studied using the available test results. Using the experimental results, the structural response parameters including ductility, response modification factor and displacement amplification factor are determined for different types of walls including fully grouted, partially grouted, ungrouted walls, walls with confinement plates, walls with supplemental mild steel and walls with an opening.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.