BackgroundSepsis is a potentially life-threatening, systemic complication of infection. Rapid intervention is critical to reduce morbidity and mortality; however, early recognition of sepsis is challenging due to a highly variable and nonspecific presentation. Recognition is particularly problematic in ambulatory (walk-in) patients who receive minimal to no medical attention prior to ED presentation. There is limited literature addressing sepsis intervention among the ambulatory population in the ED. Our organization has employed an electronic, nurse-driven sepsis screening tool into the triage process for all ambulatory patients who present to the ED.MethodsThis was a retrospective, quasi-experimental study conducted from November 2015 to May 2018 in three consecutive timeframes: pre-implementation (12 months), implementation (7 months), and post-implementation (12 months). Adult ambulatory ED patients were included if they had a coded diagnosis of sepsis, septic shock, or an infectious syndrome, had fever or hypothermia and systemic inflammatory response syndrome signs on presentation. The primary outcome measure was hourly time interval to antibiotic administration from time of ED registration.ResultsA total of 902 patients were included with 286, 208, and 408 patients in the pre-implementation, implementation and post-implementation cohorts, respectively. Baseline characteristics including comorbid conditions and infection source were similar between cohorts. The primary outcome of hourly time interval to antibiotic administration was significantly different (P = 0.044) between the three cohorts with the most substantial increase in administration specifically in the less than 1-hour interval. Between the pre-implementation, implementation, and post-implementation cohorts, significant decreases were observed in mean time to fluids (3.6, 3.0, and 2.5 hours, respectively, P = 0.003) and average length of stay (5.5, 5.8, and 4.2 days, respectively, P < 0.001) and a significant increase was observed in ED sepsis alert activations (26%, 48%, 51%, respectively, P < 0.001).ConclusionA nurse-driven electronic time-of-triage sepsis screening tool improved timely recognition and intervention in ambulatory ED patients with suspected sepsis. Disclosures All authors: No reported disclosures.