Parameter optimization (PO) methods to determine the ionic current composition of experimental cardiac action potential (AP) waveform have been developed using a computer model of cardiac membrane excitation. However, it was suggested that fitting a single AP record in the PO method was not always successful in providing a unique answer because of a shortage of information. We found that the PO method worked perfectly if the PO method was applied to a pair of a control AP and a model output AP in which a single ionic current out of six current species, such as IKr, ICaL, INa, IKs, IKur or IbNSC was partially blocked in silico. When the target was replaced by a pair of experimental control and IKr-blocked records of APs generated spontaneously in human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs), the simultaneous fitting of the two waveforms by the PO method was hampered to some extent by the irregular slow fluctuations in the Vm recording and/or sporadic alteration in AP configurations in the hiPSC-CMs. This technical problem was largely removed by selecting stable segments of the records for the PO method. Moreover, the PO method was made fail-proof by running iteratively in identifying the optimized parameter set to reconstruct both the control and the IKr-blocked AP waveforms. In the lead potential analysis, the quantitative ionic mechanisms deduced from the optimized parameter set were totally consistent with the qualitative view of ionic mechanisms of AP so far described in physiological literature.