IntroductionIatrogenic injury to the larynx, particularly the vocal cords from prolonged intubation, has been well-studied; however, tracheal injuries are rarely reported. This study investigates the effectiveness of cuffed, high-volume, low-pressure endotracheal tubes in preventing the development of tracheal ulcers in intubated subjects. MethodsA retrospective, IRB-approved review was performed on 1355 subjects who underwent percutaneous tracheostomy from 2002 to 2018. The presence and severity of tracheal ulcers were collected using documentation and photos during percutaneous tracheostomy placement. Primary outcome measures included: the length of time on a ventilator until tracheostomy (LOVT), length of hospitalization (LOH), and mortality in relationship to the severity of the tracheal injury. Data was reported as n (%) and median (IQR). The differences in means between groups were analyzed by ANOVA and Chi-square test with an alpha of 0.05. Results206 subjects met the inclusion criteria; 65 subjects had an absence of tracheal injury, and 141 subjects developed tracheal ulcers. Subjects with tracheal ulcers were grouped by the following severity scale: no ulcer; mild ulcer (minimal mucosal erosion with exudate); moderate ulcer (mucosal erosion); and severe (tracheal ring exposure). There were no statistically significant differences in age (p = 0.99), gender (p = 0.83), BMI (p = 0.44), LOH (p = 0.88), LOVT (p = 0.93), and mortality (p = 0.306) between subjects with differing severity of ulcers. The average annual incidence of clinically significant ulcers (moderate and severe) was 2.2 %. ConclusionsThe lack of statistical correlation between the duration of intubation and tracheal ulcer severity, along with a low annual incidence of tracheal ulcers, supports the improved safety of high-volume, low-pressure cylindrical, cuffed endotracheal tubes. This study is among the first to specifically focus on injuries at the level of the cuff and tip of endotracheal tubes with implications in preventive measures and potential product design changes.