The paper describes a novel technique for pipe testing based on visualization of parametric pseudo-spectral characteristics of segmented signals from a magnetic-induction flaw detector. As compared with the method of fast spectral Fourier analysis, the new approach provides higher sensitivity and reliability of flaw detection in the presence of notable structural and signal noise. Results of experimental tests of the technique are given.