It has been suggested previously that the presence of Probst bundles (PB) in cases with a short corpus callosum (SCC) on diffusion tensor imaging (DTI) may help to differentiate between corpus callosal (CC) dysplasia and a variant of normal CC development. The objectives of this study were to compare DTI parameters between cases of SCC vs normal CC and between cases of SCC with PB (SCC-PB+) vs SCC without PB (SCC-PB-). This was a retrospective study of patients referred to the Necker Hospital in Paris, France, for magnetic resonance imaging (MRI) evaluation of an apparently isolated SCC detected by sonography between November 2016 and December 2022 (IRB: 00011928). MRI was performed using a 1.5-Tesla Signa system. T2-weighted axial and sagittal sequences of the fetal brain were used to measure the length and thickness of the CC. 16-direction DTI axial brain sequences were performed to identify the presence of PB and to generate quantitative imaging parameters (fractional anisotropy (FA) and apparent diffusion coefficient (ADC)) of the entire CC, genu, body and splenium. Cases in which other associated brain abnormalities were detected on MRI were excluded. Cases were matched for fetal gender and gestational age with controls in a 1:3 ratio. Control cases were normal fetuses included in the LUMIERE on the FETUS trial (NCT04142606) that underwent the same DTI evaluation of the brain. Comparisons between SCC and normal CC cases, and between SCC-PB+ and SCC-PB- cases were performed using ANOVA and adjusted for potential confounders using ANCOVA. Twenty-two SCC cases were included and compared with 66 fetuses with a normal CC. In 10/22 (45.5%) cases of SCC, PB were identified. As expected, dimensions of the CC were significantly smaller in SCC compared with normal CC cases (all P < 0.01). In SCC-PB+ vs SCC-PB- cases, FA values were significantly lower in the entire CC (median, 0.21 (range, 0.19-0.24) vs 0.24 (range, 0.22-0.28); P < 0.01), genu (median, 0.21 (range, 0.15-0.29) vs 0.24 (range, 0.17-0.29); P = 0.04), body (median, 0.21 (range, 0.18-0.23) vs 0.23 (range, 0.21-0.27); P = 0.04) and splenium (median, 0.22 (range, 0.16-0.30) vs 0.25 (range, 0.20-0.29); P = 0.03). ADC values were significantly higher in the entire CC, genu and body in SCC-PB+ vs SCC-PB- cases (all P < 0.05). In SCC-PB+ cases, all FA values were significantly lower, and ADC values in the CC body were significantly higher compared with normal CC cases (all P < 0.05). In SCC-PB- cases, there was no significant difference in FA and ADC compared with normal CC cases (all P > 0.05). Fetal DTI evaluation of the CC showed that FA values were significantly lower and ADC values tended to be significantly higher in SCC-PB+ compared with normal CC cases. This may highlight alterations of the white matter microstructure in SCC-PB+. In contrast, isolated SCC-PB- did not demonstrate significant changes in DTI parameters, strengthening the possibility that this is a normal CC variant. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.
Read full abstract