BackgroundRecognizing the limitations of pre-market clinical data, regulatory authorities have embraced total product lifecycle management with post-market surveillance (PMS) data to assess medical device safety and performance. One method of proactive PMS involves the analysis of real-world data (RWD) through retrospective review of electronic health records (EHR). Because EHRs are patient-centered and focused on providing tools that clinicians use to determine care rather than collecting information on individual medical products, the process of transforming RWD into real-world evidence (RWE) can be laborious, particularly for medical devices with broad clinical use and extended clinical follow-up. This study describes a method to extract RWD from EHR to generate RWE on the safety and performance of embolization coils.MethodsThrough a partnership between a non-profit data institute and a medical device manufacturer, information on implantable embolization coils’ use was extracted, linked, and analyzed from clinical data housed in an electronic data warehouse from the state of Indiana’s largest health system. To evaluate the performance and safety of the embolization coils, technical success and safety were defined as per the Society of Interventional Radiology guidelines. A multi-prong strategy including electronic and manual review of unstructured (clinical chart notes) and structured data (International Classification of Disease codes), was developed to identify patients with relevant devices and extract data related to the endpoints.ResultsA total of 323 patients were identified as treated using Cook Medical Tornado, Nester, or MReye embolization coils between 1 January 2014 and 31 December 2018. Available clinical follow-up for these patients was 1127 ± 719 days. Indications for use, adverse events, and procedural success rates were identified via automated extraction of structured data along with review of available unstructured data. The overall technical success rate was 96.7%, and the safety events rate was 5.3% with 18 major adverse events in 17 patients. The calculated technical success and safety rates met pre-established performance goals (≥ 85% for technical success and ≤ 12% for safety), highlighting the relevance of this surveillance method.ConclusionsGenerating RWE from RWD requires careful planning and execution. The process described herein provided valuable longitudinal data for PMS of real-world device safety and performance. This cost-effective approach can be translated to other medical devices and similar RWD database systems.